Round duct system

Ventilation access doors and inspections

manufacturer: Akvilon | Kods: VASINLU

Ventilation Inspection Hatches (Round and Rectangular)

Description

An inspection hatch is an airtight access door installed on air ducts to provide quick and easy access to the interior of the system (for inspection, cleaning, or disinfection). We offer two types of solutions:

  • For round ducts: The hatch has a curved (radius) frame profile, allowing it to fit tightly around the pipe.
  • For rectangular ducts: The hatch has a flat frame for installation on the flat surface of a ventilation duct.

Key Features

  • Airtightness: The hatches are equipped with an elastic gasket that ensures a high class of airtightness.
  • Easy Installation: A self-adhesive cutting template is included. The hatch is secured with two rotating knobs, requiring no additional tools.
  • Material: Galvanized steel (DX51+Z275). Stainless steel or aluminium versions available on request.

Technical Specifications and Article Numbers

Below are the compatibility tables and mounting hole dimensions for both types of hatches.

Hatches for round ducts (curved)

Article For pipe diameter (mm) Hole size AxB (mm)
VASTL0125 100 - 125 180 x 80
VASTL0160 160 - 180 200 x 100
VASTL0200 180 - 200 250 x 150
VASTL0250 250 250 x 150
VASTL0315 315 250 x 150
VASTL0400 400 300 x 200
VASTL0500 500 300 x 200

Hatches for rectangular ducts (flat)

Article Hole size AxB (mm)
VASTL1808 180 x 80
VASTL2010 200 x 100
VASTL2515 250 x 150
VASTL3020 300 x 200
VASTL4020 400 x 200
VASTL4030 400 x 300
VASTL5040 500 x 400

Materials and Standards:

  • Material: Galvanized steel DX51+Z275.
  • Steel thickness: 0.7–1.2 mm (depending on size).
  • Compliance: EN 1506:2007, PN-EN 12097.

Availability

  • In Stock: We keep stock of hatches for pipe diameters from 100 to 500 mm.
  • On Order: We manufacture hatches for large diameters (over 500 mm), as well as products made of stainless steel and aluminium.

Application and Installation

  • Installation: The hatch is installed directly onto the duct wall (round or rectangular). A hole must be cut according to the shape of the gasket (dimensions $A times B$ are indicated in the table).
  • Fixation: The hatch is inserted into the opening and tightened with the rotating knobs, which ensure secure fixation and airtightness.

© 2012-2025 SIA "AKVILON"
e-mail: info@akvilon.lv | phone: +371 26336845, +371 20125412 | www.akvilon.eu | www.dumvadi.lv | e-shop - shop.akvilon.eu |