Pellet Stove Chimneys (SPNP)

SPNP Black tee 90°

manufacturer: PRODMAX | Kods: PRGRASPNP08

SPNP 90° Black Steel Tee for Pellet Stove & Boiler Flues

Product Description

The SPNP 90° Tee is a black carbon steel chimney tee used to connect a horizontal flue section from a pellet appliance to the main vertical run. It creates a 90-degree junction for the flue gases and features three connection points. The top and side outlets are sockets with gaskets, while the bottom outlet is a spigot designed for fitting an inspection cap or a condensate drain, providing easy access for system maintenance. Suitable for pellet stoves, pellet boilers, and other low-temperature, fan-assisted heating appliances.

Key Features

  • Main Line Connection: Allows a horizontal run from the appliance to be safely and securely connected into the main vertical flue or chimney.
  • Inspection and Drainage Access: The bottom spigot outlet is designed for fitting an inspection cap or a condensate drain (purchased separately), which simplifies system maintenance and moisture removal.
  • Pressure-Tight Seal for Modern Heating Systems (Class P1): Our flue system is designed specifically for fan-assisted and forced draught boilers. The socket connections with pre-installed silicone gaskets are essential for these power-vented appliances, where flue gases are expelled under positive pressure.
  • European Quality and Safety: The product is certified and CE marked, confirming its full compliance with the European standard for flue systems EN 1856-2.

Technical Specifications

Parameter Value
Article PRGRASPNP08080
Component Type 90° Tee Piece
Inner Diameter Ø 80 mm
Branch Angle 90 degrees
Material Grade Carbon Steel DC01
Wall Thickness 1.2 mm
Seal 2 Silicone gaskets (on top and side sockets)
Temperature Class T200 (up to 200°C)
Pressure Class P1 (pressure-tight)
Availability In Stock

Important Limitations

  • For Pellet Appliances Only: Do not use with wood-burning stoves, open fireplaces, or other solid fuel boilers where flue gas temperatures exceed 200°C and there is a risk of soot fire.
  • Requires Bottom Cap/Drain: The bottom outlet of the tee must be fitted with an inspection cap or a condensate drainage system. Leaving it open is prohibited.
  • For Indoor Installation Only: This is not an insulated (twin-wall) pipe and is intended for installation only inside heated spaces.