lv ru en

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Components


Sort by:  
Manufacturer:
Plastic Blind Plug
Artikuls: PRSK05
PRODMAX
Ventilācijas plastmasas noslēgvāks;Пластиковая заглушка;Plastic Blind Plug. cnt. 0.00 Ls
PRODMAX
Gumijas savienojuma uzmava GM sistēmai;Резиновая соединительная муфта для системы GM;Rubber connection sleeve for GM systems. cnt. 0.00 Ls
Artikuls: DNSMLB075
PRODMAX
Blīvgredzens lokanajiem gaisa vadiem;Уплотнительное кольцо для гибких воздуховодов;;Sealing ring for flexible air ducts. cnt. 0.00 Ls
PRODMAX
Plastmasas turētājs lokanajiem gaisa vadiem;Пластиковый держатель для гибких воздуховодов;Plastic holder for flexible air ducts. cnt. 0.00 Ls
Plastic connection sleeve
Artikuls: PRSK03OC
PRODMAX
Cietās plastmasas savienojuma uzmava;Пластиковая соединительная муфта;Plastic connection sleeve. cnt. 0.00 Ls
PRODMAX
Gumijas noslēgvāks sadales kolektoriem;Резиновая заглушка для распределительных коллекторов;Rubber plug for distribution manifolds. cnt. 0.00 Ls
Reinforced aluminium tape
Artikuls: PRSK045050350
PRODMAX
Pastiprināta alumīnija lente;Армированная алюминиевая лента;Reinforced aluminium tape. cnt. 0.00 Ls
PRODMAX
Regulējams iekškanāla vārsts ar trokšņu slāpētāju;Регулируемый внутриканальный клапан с шумоглушителем;Adjustable in-duct valve with silencer. cnt. 0.00 Ls
Smooth aluminium tape
Artikuls: PRSK045050
PRODMAX
Gluda alumīnija lente;Гладкая алюминиевая лента;Smooth aluminium tape. cnt. 0.00 Ls
Conical filters
Artikuls: PRFSA
PRODMAX
Konusveida filtri;Конусные фильтры;Conical filters. cnt. 0.00 Ls
Artikuls: PRSK10BL
PRODMAX
Griezējs lokanajiem gaisa vadiem;Резак для гибких воздуховодов;;Cutter for flexible air ducts. cnt. 0.00 Ls
Perforated mounting tape
Artikuls: PRSK08
PRODMAX
Perforēta montāžas lente;Перфорированная монтажная лента;Perforated mounting tape. cnt. 0.00 Ls

Ancillary Components for Heat Recovery Systems

The Importance of Every Component

A high-efficiency and durable heat recovery ventilation system is more than just a heat recovery unit and ductwork. It is a complex engineering ecosystem where performance, quietness, and energy efficiency depend on the quality of every single, even the smallest, element. This section is dedicated to the details that distinguish a professionally assembled system from an amateur one.

Here you will find components compatible with the various technologies of our systems: all-metal (OC), with rubber seals (GM), hybrid (PK), and all-plastic (TPK).


Functional Groups of Components

All components in this section are grouped by their primary function.

Components for System Airtightness (Class D)

Achieving the highest airtightness class, D, is a mandatory condition for an energy-efficient system. Air leaks lead to colossal heat loss and force the fan to consume 25-45% more energy. The following are used to create airtight connections:

  • EPDM Gaskets: Installed at the connection points of flexible ducts with plenum boxes and manifolds, ensuring a tight and durable fit.
  • Aluminum Tapes: Reinforced and smooth tapes are used for additional sealing of joints, vapor barriers, and protection of insulation materials. They possess high strength and heat resistance.
  • Connectors, End Caps, and Covers: Couplings for connecting ducts (e.g., for GM and OC systems), end caps for unused manifold spigots, and covers ensure the integrity and airtightness of the entire network.

Elements for Balancing and Regulation

A balanced system is one where the supply air volume equals the extract air volume, and each room receives the exact amount of air specified by the design. This requires:

  • Regulating Dampers: Typically installed in plenum boxes, they allow for precise adjustment of the resistance in each branch of the system, thereby regulating the volume of airflow. This is a critical element for commissioning and proper ventilation performance.

Filters for Air Quality (IAQ)

The purity of the supplied air is one of the main goals of ventilation. In addition to the main filters in the heat recovery unit, supplementary filtration stages are used:

  • Cone Filters: Installed in the plenum box at the inlet to the diffuser, they serve as an additional barrier for dust that may have settled in the ducts during installation. They are easy to replace and maintain.

Mounting and Fastening Materials

Secure fastening of all system elements prevents vibrations, duct sagging, and loss of connection airtightness.

  • Pipe Holders: Special clips for quick and reliable fastening of flexible ducts to the floor, wall, or ceiling.
  • Perforated Strap: A universal fastening element for suspending rigid ducts, manifolds, and other equipment.
  • Tools: Specialized blades for clean and fast cutting of flexible ducts.

Summary Table of Functions and Products

Task Key Product Solutions
Ensuring Airtightness (Class D) EPDM gaskets, reinforced and smooth aluminum tapes, connectors, end caps, covers.
Precise Airflow Balancing Regulating dampers.
Additional Air Filtration Cone filters for plenum boxes.
Reliable System Mounting and Fastening Pipe holders, perforated strap.
Cutting and Processing Components Specialized blades, tools.

Professional Selection and Installation

Unsure which specific components are needed for your project? Our engineers will help you specify the system correctly. We also provide professional installation of all components with a guarantee of airtightness and efficiency.


CE Mark Akvilon

CE Certification and ErP Compliance

All ventilation units and system components supplied by Akvilon are CE marked, confirming their full compliance with EU regulations, including the Ecodesign Directive (ErP). This is your guarantee of the equipment's safety and efficiency.


Go to Component Selection

Browse the full range of ancillary components in our online store or contact our specialists for a consultation.


© 2012-2025 SIA "AKVILON"
e-mail: info@akvilon.lv | phone: +371 26336845, +371 20125412 | www.akvilon.eu | www.dumvadi.lv | e-shop - shop.akvilon.eu |