Stainless Steel Chimneys - IZOKOMPAKT

Insulated flue pipe 500mm

manufacturer: AKVILON | Kods: DN500

Insulated Twin-Wall Chimney Pipe IZOKOMPAKT (500 mm)

Product Description

The 500 mm straight insulated pipe is a primary component for constructing IZOKOMPAKT double-wall insulated chimney (twin-wall flue) systems. It is used to create vertical and horizontal sections of the flue, and to precisely achieve the required overall height or length of the system. The elements connect using a socket-and-spigot (push-fit) system, ensuring simple installation and a perfectly sealed flue.

Key Features

  • Three-Layer Sandwich Construction: An inner pipe made of acid-resistant stainless steel, a 50 mm thick layer of high-density non-combustible basalt wool insulation, and a protective outer casing. This structure ensures the flue heats up quickly, promoting a stable draft and minimizing condensate formation.
  • Fire Safety: Due to the effective insulation, the outer surface temperature remains low, allowing the chimney to be safely passed through combustible walls, floors, and roofs. The minimum safe distance to combustible materials is 100 mm.
  • Reliable and Simple Connection: The precision of the push-fit connection guarantees a quick and easy chimney assembly. Each joint is additionally secured with a locking band for maximum rigidity and a perfect seal.
  • Material & Finish Options: The outer casing is available in classic stainless steel, an economical galvanized steel finish, or painted in any popular RAL colour, allowing the chimney to perfectly match the building's exterior.

Available Diameters & Specifications

Main parameters for the L=500 mm pipe
Inner / Outer Diameter (mm) 100/200 120/220 130/225 150/250 160/250 180/280 200/300
Article DNADN5010 DNADN5012 DNADN5013 DNADN5015 DNADN5016 DNADN5018 DNADN5020
Inner Pipe Material Stainless Steel (AISI 304 / AISI 316L)
Insulation Basalt Wool (50 mm, 100 kg/m³)
Outer Casing Material Stainless Steel / Galvanized Steel / Painted Steel (RAL)
Temperature Class T600 (up to 600°C)
Sootfire Resistance Class G
Min. Distance to Combustibles 100 mm

Application & Installation Rules

  • Primary Component: Used to create the straight sections of the chimney system.
  • Mandatory Securing: Every joint between pipes must be securely fastened with a locking band.
  • Maintain Clearances: During installation, the minimum distance of 100 mm from the outer casing of the pipe to any combustible materials must be strictly maintained.

© 2012-2025 SIA "AKVILON"
e-mail: info@akvilon.lv | phone: +371 26336845, +371 20125412 | www.akvilon.eu | www.dumvadi.lv | e-shop - shop.akvilon.eu |