| Stainless Steel Chimneys - IZOKOMPAKT
Rain Cap with Spark Guard for Chimney
Product Description
The Rain Cap with Spark Guard is a specialized top component for three-layer chimneys that performs two functions: it protects the channel from precipitation and prevents hot sparks from escaping. Its primary function is to act as a spark arrestor. This is a mandatory component for saunas, open fireplaces, or in cases where the roof or nearby buildings are made of combustible materials.
Key Features
- Effective Spark Protection: The principle is simple and reliable. The flow of flue gases with sparks first hits the cap, changing direction, and then passes through the fine-mesh screen. The spark guard breaks up and extinguishes embers upon contact with the metal mesh.
- Protection from Precipitation and Birds: It performs all the functions of a standard rain cap—protecting from rain and snow. Additionally, the mesh serves as an impassable barrier for birds and small animals that might try to build a nest in the insulated chimney.
- Reliable Construction: It is manufactured as standard from heat-resistant stainless steel AISI 304 / 316L with a thickness of 0.6 mm. The mesh size (10x10 mm or 20x20 mm) is large enough for the free passage of smoke but effective for catching sparks.
- Optimized to Preserve Draft: Like a standard rain cap, the spark arrestor is designed to have a minimal effect on the draft, provided that the mesh is cleaned regularly.
Technical Specifications
Main parameters of the Rain Cap with Mesh
Purpose |
Spark arresting, protection of the flue channel from precipitation and debris |
Installation Point |
Into the inner pipe at the highest point of the chimney (after the cone) |
Material (standard) |
Stainless Steel AISI 304 / 316L (thickness 0.6 mm) |
Mesh Size |
10x10 mm or 20x20 mm |
Articles & Available Diameters
Articles for the Rain Cap with Mesh (Spark Arrestor)
Inner Chimney Diameter (D), mm |
80 |
100 |
120 |
130 |
150 |
160 |
180 |
200 |
Article |
DVJVA0080 |
DVJVA0100 |
DVJVA0120 |
DVJVA0130 |
DVJVA0150 |
DVJVA0160 |
DVJVA0180 |
DVJVA0200 |
* Spark arrestors for chimneys with an inner diameter of more than 200 mm are available on request.
Application & IMPORTANT RESTRICTIONS
- REQUIRES REGULAR CLEANING: Over time, the spark arrestor mesh will become clogged with soot. A clogged mesh severely impairs the draft and can lead to smoke entering the room. It is necessary to inspect and clean the mesh regularly (at least 1-2 times per season).
- Fuel Restrictions: It is strongly recommended not to use the spark arrestor when burning resinous woods (pine, spruce) or damp firewood, as this leads to rapid clogging of the mesh with creosote.
- Alternative Solution: If spark arresting is not a mandatory requirement, it is recommended to use a standard rain cap (cowl) for better draft and simpler maintenance.
|
|