Stainless Steel Chimneys - IZOKOMPAKT

Rain cap with spark guard

manufacturer: AKVILON | Kods: JVA

Rain Cap with Spark Guard for Chimney

Product Description

The Rain Cap with Spark Guard is a specialized top component for three-layer chimneys that performs two functions: it protects the channel from precipitation and prevents hot sparks from escaping. Its primary function is to act as a spark arrestor. This is a mandatory component for saunas, open fireplaces, or in cases where the roof or nearby buildings are made of combustible materials.

Key Features

  • Effective Spark Protection: The principle is simple and reliable. The flow of flue gases with sparks first hits the cap, changing direction, and then passes through the fine-mesh screen. The spark guard breaks up and extinguishes embers upon contact with the metal mesh.
  • Protection from Precipitation and Birds: It performs all the functions of a standard rain cap—protecting from rain and snow. Additionally, the mesh serves as an impassable barrier for birds and small animals that might try to build a nest in the insulated chimney.
  • Reliable Construction: It is manufactured as standard from heat-resistant stainless steel AISI 304 / 316L with a thickness of 0.6 mm. The mesh size (10x10 mm or 20x20 mm) is large enough for the free passage of smoke but effective for catching sparks.
  • Optimized to Preserve Draft: Like a standard rain cap, the spark arrestor is designed to have a minimal effect on the draft, provided that the mesh is cleaned regularly.

Technical Specifications

Main parameters of the Rain Cap with Mesh
Purpose Spark arresting, protection of the flue channel from precipitation and debris
Installation Point Into the inner pipe at the highest point of the chimney (after the cone)
Material (standard) Stainless Steel AISI 304 / 316L (thickness 0.6 mm)
Mesh Size 10x10 mm or 20x20 mm

Articles & Available Diameters

Articles for the Rain Cap with Mesh (Spark Arrestor)
Inner Chimney Diameter (D), mm 80 100 120 130 150 160 180 200
Article DVJVA0080 DVJVA0100 DVJVA0120 DVJVA0130 DVJVA0150 DVJVA0160 DVJVA0180 DVJVA0200

* Spark arrestors for chimneys with an inner diameter of more than 200 mm are available on request.

Application & IMPORTANT RESTRICTIONS

  • REQUIRES REGULAR CLEANING: Over time, the spark arrestor mesh will become clogged with soot. A clogged mesh severely impairs the draft and can lead to smoke entering the room. It is necessary to inspect and clean the mesh regularly (at least 1-2 times per season).
  • Fuel Restrictions: It is strongly recommended not to use the spark arrestor when burning resinous woods (pine, spruce) or damp firewood, as this leads to rapid clogging of the mesh with creosote.
  • Alternative Solution: If spark arresting is not a mandatory requirement, it is recommended to use a standard rain cap (cowl) for better draft and simpler maintenance.