Roof Flashing for Chimneys (Roof Penetration Plate)

Product Description

The Roof Flashing (also known as a roof penetration plate or "apron") is a key waterproofing component for a twin-wall chimney, ensuring a sealed and safe passage of the pipe through the roof structure. It consists of a metal base plate and an integrated cone that fits tightly around the pipe, reliably protecting the roof space from moisture ingress.

Key Features

  • Complete Waterproofing: A correctly installed roof flashing completely eliminates leaks at the junction of the chimney and the roof by diverting rain and meltwater.
  • Selection by Exact Roof Pitch: The components are manufactured for different ranges of roof slope. Choosing the correct angle ensures that the cone will be perfectly vertical, providing minimal gaps and a proper installation.
  • Durable Materials: It is made from the same materials as the outer casing of the insulated chimney (stainless steel, galvanized steel, or painted steel), ensuring a uniform appearance and long service life.
  • System Solution: To be fully sealed, the roof flashing assembly must be completed with a rain collar (storm collar), which is installed on the pipe directly above the cone.

How to Choose the Correct Angle?

The choice of component depends on the pitch (slope) of your roof. We offer four standard options, each available for purchase in our e-shop:

Articles & Available Diameters

The table below provides the articles for each diameter based on the selected roof pitch.

Summary table of articles for Roof Flashing
Diameter (Inner/Outer) Article (Pitch 0-5°) Article (Pitch 5-20°) Article (Pitch 20-35°) Article (Pitch 35-50°)
100/200 DN1JI0510 DN1JI2010 DN1JI3510 DN1JI5010
120/220 DN1JI0512 DN1JI2012 DN1JI3512 DN1JI5012
130/225 DN1JI0513 DN1JI2013 DN1JI3513 DN1JI5013
160/250 DN1JI0516 DN1JI2016 DN1JI3516 DN1JI5016
180/280 DN1JI0518 DN1JI2018 DN1JI3518 DN1JI5018
200/300 DN1JI0520 DN1JI2020 DN1JI3520 DN1JI5020

Important Installation Notes

  • Correct Layering: The base plate of the roof flashing should be installed under the roofing material on the side closer to the ridge, and over the roofing material on the side closer to the eaves, to ensure proper water drainage.
  • Sealing: It is recommended to additionally seal the areas where the plate adjoins the roofing material with a suitable roofing sealant.
  • Mandatory Use of a Rain Collar: Without the installation of a rain collar (storm collar), the penetration point will not be sealed. It is a mandatory accompanying component.