Stainless Steel Chimneys - IZOKOMPAKT

Bottom adapter "-"

manufacturer: AKVILON | Kods: ADM

Insulated Bottom Adapter with Spigot

Product Description

The Bottom Adapter with Spigot (or transition piece) is the initial component of a twin-wall (insulated) IZOKOMPAKT chimney system. It is designed to transition from a single-wall flue pipe to a twin-wall system using the modern 'by condensate' principle. Its key feature is a lower narrowed spigot, which is inserted into the single-wall pipe from the boiler or stove. This assembly ensures that condensate running down the inner walls of the chimney remains inside the flue and does not leak out at the joint.

Key Features

  • Connection with Spigot ('By Condensate'): The spigot design provides a male-female connection where the adapter acts as the 'male' part. This is the modern installation standard that completely protects joints from condensate leakage.
  • Standalone Transition Component: This element allows you to start the insulated section of the chimney at any required point—for example, when transitioning from a single-wall pipe to a twin-wall section just before passing through a ceiling.
  • Reliable Insulation: Immediately after the adapter, the flue gases enter an insulated channel, which maintains their high temperature, promotes stable draft, and minimizes condensate formation.
  • Versatile Installation: It can be installed directly onto the outlet of the heating appliance or onto a single-wall pipe.

Available Diameters & Specifications

Main parameters for the Bottom Adapter with Spigot
Inner / Outer Diameter (mm) 100/200 120/220 130/225 150/250 160/250 180/280 200/300
Article DNAADS10 DNAADS12 DNAADS13 DNAADS15 DNAADS16 DNAADS18 DNAADS20
Inner Pipe Material Stainless Steel AISI 304L / 316L (thickness from 0.6 mm)
Outer Casing Material Stainless, Galvanized or Painted Steel (RAL catalogue)
Insulation Non-combustible Basalt Wool (50 mm thick, 100 kg/m³ density)
Connection Type With Spigot (adapter is inserted into the single-wall pipe)
Purpose Bottom (start) component, transition from single-wall to twin-wall pipe

Application & Alternative Solutions

  • Standard for Boilers: This connection type is the standard for most modern heating boilers (gas, pellet, diesel) that operate with condensate formation.
  • Alternative Solution: For some wood-burning stoves, where a smooth smoke path without an internal step is important, an adapter with a socket is used.